AHU - Air quality and comfort: anytime, anywhere
Pressurised water humidifiers
The Air Handling Unit (AHU) market is growing at a fast pace worldwide, driven by the stricter requirements of standards and regulations.
 
CAREL solutions for hospitals and healthcare structures
Pressurised water humidifiers
Control and management of air humidification in healthcare structures is needed to reduce the risk of contagion and ensure the comfort of healthcare workers, patients and visitors.
 
Humidification technologies - Adiabatic
Pressurised water humidifiers
Adiabatic humidifiers bring about the direct evaporation of water into the air without adding external energy, and therefore without raising the temperature; the heat required for evaporation is...
 

optiMist

EC*
optiMist
optiMist optiMist optiMist optiMist
 
  • General characteristics

    optiMist is a humidifier and adiabatic evaporative cooler that, by atomizing water into small droplets, allows the latter to evaporate spontaneously, subtracting heat from the humidified air, which is cooled at the same time. The system consists of a cabinet, inside which there is a flap valve pump, with pressures up to 15 bar, and an atomized water distribution rack, to be installed inside the air treatment unit.

     

    The sophisticated control system managed by the pCO, which combines the action of the inverter (that regulates the speed and therefore the flow of the pump) and that of the two solenoid valves, which activate only the nozzles that are necessary, allowing the system to operate always at optimum pressure in a wide flow range. The two solenoid valves (placed inside the cabinet) divide the distribution into two independent steps, which can be simultaneously present on the same rack (acting one after the other sequentially) forming two steps of continuous modulation, or they can be separated in two different distribution systems, each with a single step, supplying two different areas: this is the typical case of the application of humidification + direct adiabatic cooling in the input duct and indirect adiabatic cooling in the output duct, with heat exchanger between the two air treatment units.


    The optiMist cabinet is available in the following capacities: 50, 100, 200, 400, 800 e 1000 l/h. The distribution system can be selected from a large list of available codes, depending on the size of the duct and the atomization required. optiMist can be used with demineralized water, but also with mains water, as long as the unit is cleaned more frequently

  • Plus

    • two areas that can be controlled by a single cabinet, without the need for a secondary control panel: ideal for the application of direct and indirect Evaporative Cooling
    • energy saving and possibility to reduce the time of use of mechanical cooling
    • inverter that allows an accurate and efficient modulation
    • two modulation steps to increase the accuracy of applications in a single area
    • drainage valves and flushing cycles to avoid water stagnation
    • sterile materials used which do not contribute to bacterial growth
    • can be used with demineralized water, softened water or mains water